CONTROL PANELS
Parameter
Mnemonic
Description
Table 1
Default
Value
(Celsius)
Table 2 Default
Value
(Fahrenheit)
Units
P 1
Input table
2 10
P 2
Low scale range of sensors
0 ºc 0 ºf
Degrees
P 3
High scale range of sensors
282 ºc 540 ºf
Degrees
P 4
Output 1 control action
reu reu
P 5
Output 2 function
1 1
P 6
Output 2 alarm type
h.r. h.r.
P 8
Alarm 1 standby function
Off Off
P11
Auto-ranging display
Off Off
P1 2
Filter sensor values
On On
P22
Output 3 function
1 1
P23
Output 3 alarm type
h.r. h.r.
P25
Alarm 2 standby function
Off Off
P33
Access to op.5 mode
55 55
P35
Access to cnf mode
415 415
P36
Access to I .cl mode
415 415
Configuration Mode Parameter Table
Loading Celsius or Fahrenheit Tables
The controller contains two default parameter tables. Table 1 is used for Celsius operation,
and Table 2 is used for Fahrenheit.
To load one of the default tables, enter the configuration mode (See instructions listed in the
Configuration Mode – cnf section listed above). When cnf is displayed, press both the UP
and DOWN buttons simultaneously. The display will show d l.f. Press the UP or DOWN
buttons to display d l.1 for table 1 (Celsius), or d l.2 for table 2 (Fahrenheit).
Press the TEMP key to enter in your selection. The display will show d l.t . This indicates
that the loading procedure has been initiated and after approximately 1 second, the loading
will be finished and the display will revert back to cnf.
Exit the supervisor mode when done.
NOTE:
See Supervisor Mode section on how to exit.
17