CONTROL PANELS
Temperature Probe Error
All probes are typically type-K probes. All temperature readings normally associated with a
type-K probe are considered valid by the controller. However, if the probes become
disconnected or otherwise open, the controller will sound the buzzer and scroll
TEMPERATURE PROBE ERROR on line 1 of the display. The second line will display
the probe number(s) of the defective probe(s).
1 is water temperature probe
2 is heater sheath temperature probe
3 is sanitizing tank probe
Pressing any key shuts the buzzer off, but will not remove the error message. The only way
to remove the error message is to resolve the probe connection problem.
When these probe errors occur, all outputs are shut off.
External DC Error
The controllers DC I/O connector has a +5VDC supply. This supply is protected against
over-currents. Should this occur, the unit will disconnect the supply and report
EXTERNAL DC ERROR. The outputs are shut down and the only way to reset this is to
resolve the problem (most likely a short). Again, pressing any key will shut off the buzzer.
Omron Messages
The Omron Inverter may have errors or warnings of its own. Here’s a list of errors flagged.
In some cases, the Omron inverter will shut down (and let the motor coast to a stop).
Error detected Message scrolled
OC
OVERCURRENT ERROR
OV
OVERVOLTAGE ERROR
OL2
INVERTER OVERLOAD ERROR
OH
INVERTER OVERHEAT ERROR
EFx/STP
EXTERNAL FAULT ERROR
Fx
INTERNAL FAULT ERROR
OL1
MOTOR OVERLOAD ERROR
OL3
OVERTORQUE ERROR
UV1
UNDERVOLTAGE ERROR
GF
GROUND FAULT ERROR
CE
COMMUNICATIONS ERROR
OFF
NO POWER ERROR