CONTROL PANELS
The parameters that can be changed follow:
Temperature Units
This setting allows a different temperature unit to be used for display. You can switch
between Celsius and Fahrenheit.
Parameter name: TEMPERATURE UNITS
Allowed values: C or F
Factory default: F
Low Speed Frequency
This setting is used to set the frequency in the Omron Inverter Controller that controls the
low pump speed.
Parameter name: PUMP LOW FREQUENCY
Allowed values: 0 to 100 Hertz
Factory default: 35
Medium Speed Frequency
This setting is used to set the frequency in the Omron Inverter Controller that controls the
medium pump speed.
Parameter name: PUMP MED FREQUENCY
Allowed values: 0 to 100 Hertz
Factory default: 50
High Speed Frequency
This setting is used to set the frequency in the Omron Inverter Controller that controls the
high pump speed.
Parameter name: PUMP HIGH FREQUENCY
Allowed values: 0 to 100 Hertz
Factory default: 68
Hold Pump Speed
This setting sets the pump speed for the Hold or Clean state.
Parameter name: HOLD PUMP SPEED
Allowed values: LOW, MED, HIGH
Factory default: LOW